Zirbus
Autoclave LVSA 50/70
Autoclave LVSA 50/70
Estimated delivery time: 6-8 weeks
Warranty: 2 years
Chamber volume: 153 L
Effective space: (Ø)500x (H)755
Loading height: 900 mm
External diameter: (W) 700 x (D) 950 mm
Heating capacity: 9 kW
Brochures
Brochures
Share
The following equipment variants are available:
Basic lab - Recommended for the sterilization of simple materials or liquids without removal to dry.
- Integrated steam generator
- SteriTouch control
Dry Lab - Recommended for the sterilization of non-infectious waste bags and materials which require intensive subsequent drying.
- Integrated steam generator
- Vacuum pump set
- SteriTouch control
Quick Lab Basic - Recommended for the sterilization of large quantities of liquids.
- Integrated steam generator
- Rapid water recoolingsystem with air-circulating fan
- SteriTouch control
Quick Lab - Recommended for the sterilization of non-infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying.
- Integrated steam generator
- Vacuum pump set
- Rapid water recoolingsystem with air-circulating fan
- SteriTouch control
Quick Lab Advanced - Recommended for the sterilization of non-infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying – this also applies to liquids in closed containers.
- Integrated steam generator
- Vacuum pump set
- Rapid water recoolingsystem with air-circulating fan
- Steam/air mixture method (SAMM)
- SteriTouch control
Safe Lab - Recommended for operation in the level S2 lab. Recommended for the sterilization of infectious waste bags and materials which require intensive subsequent drying.
- Integrated steam generator
- Vacuum pump set
- Exhaust air filtration EAF
- SteriTouch control
Complete Lab - Fully equipped laboratory autoclave for operation in the level S2 lab. Recommended for the sterilization of infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying.
- Integrated steam generator
- Vacuum pump set
- Exhaust air filtration EAF
- Rapid waterrecoolingsystem with air-circulating fan
- SteriTouch control
Explanation of the individual components
Steam generator– integrated in the housing of the autoclave. Ensures rapid heating and cooling compared to conventional heating systems.
Vacuum pump set– for mechanical removal of air and drying in vacuum. Possible methods include single-stage vacuum, fractionated vacuum, constant or pulsating drying under a vacuum.
Lifting and pivoting mechanism– makes loading and unloading of vertically loaded autoclaves easier. The load capacity is 30 kg.
Exhaust air filtration– is stipulated for the sterilization of pathogenic substances in S2/S3 laboratories, with inline condensate sterilization.
Touch display (SteriTouch control)– enables simple and intuitive operation of the autoclave. In combination with user-friendly software, the autoclave can be operated quickly but also highly variable and simple.
Steam-air mixture method– for the sterilization of tightly closed bottles and pressure-sensitive materials. An additional temperature sensor, air deflectors and a circulating air fan ensure precise temperature control and distribution.
Rapid water recooling system with air-circulating fan– allows a shortening of the recooling time by more than 80% compared to the self cooling during sterilization of liquids. This is due to an internal heat exchanger, also known as a “fast cooler”, through which water flows.
Accessories– We offer stainless steel sterilisation baskets, pails and containers which fit our various chamber designs.